-- Matomo -->
eFEDS_c001_LightCurves_softhard-V5.fits
Content of the page.
[Write text to summarize contents of this HDU]
Key | Value | Type | Comment |
---|
Name | Type | Unit | Description |
---|---|---|---|
SRCID | int16 | None | Source identification number in eFEDS catalogue |
ndata_0 | float32 | None | Number of data point in energy band 0 |
meancr_0 | float64 | counts/s | Mean count rate in energy band 0 |
meancr_err_0 | float64 | counts/s | Count rate error of mean count rate in energy band 0 |
nev_0 | float64 | None | Normalized excess variance value in energy band 0 |
nev_err_0 | float64 | None | Error of the normalized excess variance value in energy band 0 |
nev_sig_0 | float64 | sigma | Normalized excess variance in units of sigma in energy band 0 |
nev_det_0 | bool | Variability flag of Normalized excess variance in energy band 0: T=true, F=false | |
ampl_max_0 | float64 | None | Maximum amplitude variability value in energy band 0 |
ampl_sig_0 | float64 | sigma | Maximum amplitude variability in units of sigma in energy band 0 |
ampl_det_0 | bool | None | Variability flag of Normalized excess variance in energy band 0: T=true, F=false |
nbblocks_0 | float32 | None | Number of Bayesian blocks in energy band 0 |
bb_det_0 | bool | None | Variability flag of Normalized excess variance in energy band 0: T=true, F=false |
bexvar_scatt_0 | float32 | None | Bayesian excess variance value in energy band 0 |
bexvar_scatt_lo_0 | float32 | None | Bayesian excess variance lower 10 per cent percentile of the posterior in energy band 0 |
bexvar_det_0 | bool | None | Variability flag of Bayesian excess variance in energy band 0: T=true, F=false |
bexvar_scatt_hi_0 | float32 | None | Bayesian excess variance upper 90 per cent percentile of the posterior in energy band 0 |
bexvar_rate_0 | float32 | None | Bayesian excess variance mean count rate value in energy band 0 |
bexvar_rate_err_0 | float32 | None | Error of the Bayesian excess variance mean count rate in energy band 0 |
ndata_1 | float32 | None | Number of data points in energy band 1 |
meancr_1 | float64 | counts/s | Mean count rate in energy band 1 |
meancr_err_1 | float64 | counts/s | Count rate error of mean count rate in energy band 1 |
nev_1 | float64 | None | Normalized excess variance value in energy band 1 |
nev_err_1 | float64 | None | Error of the normalized excess variance value in energy band 1 |
nev_sig_1 | float64 | sigma | Normalized excess variance in units of sigma in energy band 1 |
nev_det_1 | bool | None | Variability flag of Normalized excess variance in energy band 1: T=true, F=false |
ampl_max_1 | float64 | None | Maximum amplitude variability value in energy band 1 |
ampl_sig_1 | float64 | sigma | Maximum amplitude variability in units of sigma in energy band 1 |
ampl_det_1 | bool | None | Variability flag for Maximum amplitude variability in energy band 1: T=true, F=false |
nbblocks_1 | float32 | None | Number of Bayesian blocks in energy band 1 |
bb_det_1 | bool | None | Variability flag of Bayesian blocks in energy band 1: T=true, F=false |
bexvar_scatt_1 | float32 | None | Bayesian excess variance value in energy band 1 |
bexvar_scatt_lo_1 | float32 | None | Bayesian excess variance lower 10 per cent percentile of the posterior in energy band 1 |
bexvar_det_1 | bool | None | Variability flag of Bayesian excess variance in energy band 1: T=true, F=false |
bexvar_scatt_hi_1 | float32 | None | Bayesian excess variance upper 90 per cent percentile of the posterior in energy band 1 |
bexvar_rate_1 | float32 | None | Bayesian excess variance mean count rate value in energy band 1 |
bexvar_rate_err_1 | float32 | None | Error of the Bayesian excess variance mean count rate in energy band 1 |
ndata_2 | float32 | None | Number of data points in energy band 2 |
meancr_2 | float64 | counts/s | Mean count rate in energy band 2 |
meancr_err_2 | float64 | counts/s | Count rate error of mean count rate in energy band 2 |
nev_2 | float64 | None | Normalized excess variance value in energy band 2 |
nev_err_2 | float64 | None | Error of the normalized excess variance value in energy band 2 |
nev_sig_2 | float64 | sigma | Normalized excess variance in units of sigma in energy band 2 |
nev_det_2 | bool | None | Variability flag of Normalized excess variance in energy band 2: T=true, F=false |
ampl_max_2 | float64 | None | Maximum amplitude variability value in energy band 2 |
ampl_sig_2 | float64 | sigma | Maximum amplitude variability in units of sigma in energy band 2 |
ampl_det_2 | bool | None | Variability flag for Maximum amplitude variability in energy band 2: T=true, F=false |
nbblocks_2 | float32 | None | Number of Bayesian blocks in energy band 2 |
bb_det_2 | bool | None | Variability flag of Bayesian blocks in energy band 2: T=true, F=false |
bexvar_scatt_2 | float32 | None | Bayesian excess variance value in energy band 2 |
bexvar_scatt_lo_2 | float32 | None | Bayesian excess variance lower 10 per cent percentile of the posterior in energy band 2 |
bexvar_det_2 | bool | None | Variability flag of Bayesian excess variance in energy band 2: T=true, F=false |
bexvar_scatt_hi_2 | float32 | None | Bayesian excess variance upper 90 per cent percentile of the posterior in energy band 2 |
bexvar_rate_2 | float32 | None | Bayesian excess variance mean count rate value in energy band 2 |
bexvar_rate_err_2 | float32 | None | Error of the Bayesian excess variance mean count rate in energy band 2 |
isvariable_0 | bool | None | Has significant variability in one of the four tests in energy band 0: T=true, F=false |
isvariable_1 | bool | None | Has significant variability in one of the four tests in energy band 1: T=true, F=false |
isvariable_2 | bool | None | Has significant variability in one of the four tests in energy band 2: T=true, F=false |
isvariable | bool | None | Has significant variability in one of the energy bands |
counts_0_3s | bool | Unitless | Variablity for visual inspection of the cumulative counts in band 1: below 3 sigma=F, above 3 sigma=T |
counts_1_3s | bool | Unitless | Variablity for visual inspection of the cumulative counts in band 1: below 3 sigma=F, above 3 sigma=T |
counts_2_3s | bool | Unitless | Variablity for visual inspection of the cumulative counts in band 2: below 3 sigma=F, above 3 sigma=T |
This section is the place to put references of interest.
The eROSITA data model structure for catalogues was branched from the SDSS data model for value added catalogues.