Scope
This document provides a description of the algorithm and instructions for the correct
usage of the
RADEC2XY task, which is part of
eSASS
(the
eROSITA Science Analysis Software System).
Description
Task RADEC2XY calculates X and Y sky pixel coordinates (tangential
parallel projection; pixel size: 0.05'') corresponding to the RA and DEC (J2000) event coordinates in
an eROSITA event table, given an RA and DEC projection center
provided on the command line.
Parameters
- file (string) REQUIRED
- ra0 (real) REQUIRED
- dec0 (real) REQUIRED
Input file
- EVENTS table extension of eROSITA calibrated event file
Output file
- EVENTS table extension of eROSITA calibrated event file